Commercial, Residential
A Water Loop (WLHP) system connects several heat pumps to a shared water loop. Each unit can work independently in both cooling and heating, exchanging energy with the loop. The system suits buildings with zones that have different needs, and buildings that will be extended over time. Parkair offers it with three solutions with no outdoor unit: MCWFP, MCWD SLIM and MCWD.
In large buildings such as shopping centres, hotels and offices, the different zones have very different needs, with cooling loads that remain present even in winter. Choosing the right system means weighing energy consumption and comfort, but also ease of design and installation, maintenance costs and the possibility of modifying or extending the system in the future. The Water Loop meets these needs with a shared water loop to which independent heat pumps are connected, one per zone.
Water Loop Heat Pump refers to a system in which a series of reversible water/air or water/water heat pumps is connected to a closed two-pipe hydraulic circuit: the loop. In the loop, the water circulates at a neutral temperature.
The loop water acts as the source for the individual units, which produce locally the heating or cooling energy required by their own zone. Each unit draws energy from the loop or releases energy into it, depending on whether it needs to heat or cool.
The loop temperature is kept within optimal values by a heat supplement or heat rejection system, which handles any surpluses or deficits.
Only two dedicated hydraulic pipes run through the building, which makes the system easy to design and install. Maintenance is reduced compared with other types of systems. The terminal units do not require complex work on site, which shortens installation and commissioning times.
Heating and cooling energy is produced locally by the individual units, which eliminates the waste associated with transferring it from the generator to the areas served. If a heat pump fails, the damage stays contained and does not affect the operation of the whole system.
The system serves zones with different needs at the same time, in heating or in cooling. The system can be extended as required, even in anticipation of future building expansions, and it fits into existing buildings without modifying the main distribution networks.
The Water Loop is suited to shopping centres, hotels, offices and, in general, large buildings, including hospitals and mixed-use facilities. It is used in new builds and renovations, in residential and commercial buildings. It also suits historic buildings, because it requires no invasive work.
Water/Air or Water/Water systems generally run on a once-through water supply: water is drawn in for the heat exchange and then discharged. The exceptions are cases where the unit is connected to a shared water loop (Water Loop, or WLHP) or to a recovery well. In these configurations the water is recirculated or returned to the source instead of being discharged, and net consumption drops drastically.

Three Parkair models are suited to Water Loop applications. They all share fully internal installation: no outdoor unit, and no holes or grilles on the façade. What changes is the setting, the output and the way air is distributed.
MCWFP (AiROCK Acqua) is the room monobloc for residential and HoReCa settings. It is wall-mounted in the room to be conditioned, has an output of 3.5 kW and a depth of only 17 cm. The refrigerant circuit is sealed and requires no F-Gas certification. Wi-Fi is built in. It serves a single room, with direct air distribution.
MCWD SLIM is the compact ducted monobloc, only 30 cm high. It is available in two sizes: PRK-MCWD-12 at 3.5 kW and PRK-MCWD-18 at 5.2 kW. It is installed in a plant room or false ceiling and distributes air to several rooms through ducting and/or air supply grilles, with a fan with variable static pressure that can be set during installation. It is designed for residential, HoReCa and light commercial settings, and is the solution when space in the false ceiling is limited.
MCWD covers the higher outputs, from 10 to 18 kW. It too is installed in a plant room or false ceiling, and its high static pressure motor allows long, complex ducting even with high pressure losses. It is the choice for larger commercial and HoReCa settings, or for ducted residential projects. It is available with single-phase and three-phase power supply, depending on the size.
MCWFP is the room monobloc, ideal for conditioning a single room. MCWD SLIM and MCWD distribute air to several rooms through ducting. MCWD SLIM is the compact solution, only 30 cm high, for limited false ceiling space, with outputs from 3.5 to 5.2 kW. MCWD is the one for higher outputs, from 10 to 18 kW.
A: A heat supplement or heat rejection system. The most efficient solution is an air/water or water/water heat pump upstream of the whole system. Alternatively, heat generators, evaporative towers, geothermal probes or groundwater wells can be used, also in combination.
A: No. If a heat pump fails, the damage stays contained and does not affect the operation of the whole system.
A: Yes. The system can be extended as required, even in anticipation of future building expansions.
A: Yes. It fits into existing buildings without modifying the main distribution networks, and it also suits historic buildings because it requires no invasive work.
Company
Solutions
Products
Assistance and Warranty
Copyright © 2024 - Parkair Srl - P.IVA / C.F. / N. Iscr. Al Reg. Imprese IT03755100967 | REA MI-1700813 | Cap.Soc. 10.400 € Sede Legale Via Paolo Sarpi 21 Milano 20154